Procedure

  1. Dehydrate 8 hours in an oven at about 100 to 110 °C.
  2. Or blow hot air (fan heater) ensuring internal scavenging.
  3. New machine: insulation must be 10 megohms minimum when cold.
  4. Never power a machine below 1 megohm insulation.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 100-110 °C for 8 h
  • 10 megohms min cold (new)
  • 1 megohm min

Source: Leroy-Somer manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.