Home›Repair guides›Leroy-Somer›Connecting the power supply cables to the terminal block

Leroy-Somer — Connecting the power supply cables to the terminal block

Installation

From a Leroy-Somer service manual — check it applies to your exact model before use.

Before you start

  • It is compulsory to earth the motor
  • Check no foreign body has entered the terminal box

Procedure

  1. Fit the cables with connectors suitable for the cable cross-section and terminal diameter.
  2. Crimp connectors in accordance with the connector supplier's instructions.
  3. For round connectors (LSE/FLSE 80 to 160), fit motor cable connector, power supply connector, terminal washer, Y or D link and Serpress brake nut in order.
  4. Tighten the nuts to the recommended torque.
  5. For slotted terminals (LSE 180-280), lay the mains cable in the slot under the connector and tighten to the recommended torque.
  6. Check that no nut, washer or foreign body has fallen into the terminal box or come into contact with the winding.
  7. Earth the motor inside the terminal box and at the external terminal.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Terminal block and slotted terminal tightening torques per tables
  • Max 2 connectors per terminal

Source: Leroy-Somer service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.