Home›Repair guides›Leroy-Somer›Cleaning the grease traps

Leroy-Somer — Cleaning the grease traps

Maintenance · DE and NDE grease traps (CPLS 160 HV3 / 200 HV3)

From a Leroy-Somer service manual — check it applies to your exact model before use.

Before you start

  • Do not force the encoder feet when tightening; it must remain centred on the shaft.

Procedure

  1. On DE shield: take off coupling and shaft extension key, undo CHC screws and release trap.
  2. Empty waste grease, clean trap and grease valve, then refit trap, screws, key and coupling.
  3. On NDE shield: remove 3 CHC screws from encoder protective cover.
  4. Loosen encoder driving ring screw and remove encoder with its support.
  5. Undo CHC screws holding the trap and release it, empty and clean trap and grease valve.
  6. Refit trap and CHC screws, refit encoder with support and tighten driving ring screw.
  7. Refit encoder protective cover and 3 CHC screws.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Clean traps after 5 greasings

Source: Leroy-Somer service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.