Home›Repair guides›Leroy-Somer›Checks prior to first use - mechanical checks

Leroy-Somer — Checks prior to first use - mechanical checks

Installation · Alternator

From a Leroy-Somer service manual — check it applies to your exact model before use.

Procedure

  1. Top up the cooling circuit with water before starting the machine.
  2. Check the length and tightening torque of the added bolts and that there are no leaks on the water inlet and outlet.
  3. Check that the protective grille and housing are correctly in place.
  4. Check the standard direction of rotation is clockwise as seen from the drive end (phase rotation 1 - 2 - 3).
  5. For anti-clockwise rotation, swap 2 and 3.
  6. Check that the winding connection corresponds to the site operating voltage.

Source: Leroy-Somer service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Leroy-Somer repair guides →