Procedure
- Remove the air ducts (3).
- Cut the fixing clamps of the exciter cables, disconnect E+ and E- from the exciter.
- Disconnect T1 to T6 from the terminal block (124).
- Remove the nuts on the tie rods (37).
- Remove the NDE bracket (36) using a puller, e.g. U.32 - 350 (Facom).
- Unsolder the connections.
- Check the bridge using an ohmmeter or a battery lamp.
- Replace the bridges, respecting the polarity.
- Resolder the connections.
- Fit a new O ring seal in the bracket.
- Refit the NDE bracket.
- Connect T1 to T6 from the terminal block (124).
- Replace the fixing clamps on the cables and the air ducts (3).
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Leroy-Somer service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.