Home›Repair guides›Kubota›Checking Primary Chamber

Kubota WG972-GL-E3F — Checking Primary Chamber

Testing & diagnosis · LPG vaporizer

For the Kubota WG972-GL-E3F, from the Kubota service manual.

Browse Kubota generators & specs →

Before you start

  • Treat a seal tape or liquid gasket when install each connector.

Procedure

  1. Operate the engine until is warmed up.
  2. Shut a stop solenoid valve and the engine stopped naturally.
  3. Disconnect the plug.
  4. Set the pressure gauge.
  5. Open a stop solenoid valve and the engine is started.
  6. Check the pressure.
  7. If the pressure is not within the factory specification, replace the vaporizer.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Pressure factory specification: 30 to 34 kPa (0.30 to 0.35 kgf/cm2, 4.3 to 4.9 psi)

Source: Kubota service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kubota repair guides →