Home›Repair guides›Kubota›Valve Clearance Adjustment

Kubota — Valve Clearance Adjustment

Adjustments · Cylinder head / valve train

From a Kubota service manual covering: Hurth HBW 100, Hurth HBW 125, Hurth HBW 150, Hurth HBW 250, Hurth HBW 35, Hurth HBW 50, M-25XPB, M-35B, M-40B. Check it applies to your exact model before use.

Browse Kubota generators & specs →

Before you start

  • Valve adjustments should be performed by an authorized mechanic.

Procedure

  1. Remove the valve rocker cover and the glow plugs.
  2. Rotate crankshaft slowly; watch No.1 intake valve open then close.
  3. Position the TDC mark in alignment with the notch in the timing hole.
  4. Adjust the valves in Cylinder No.1.
  5. Three-cylinder: rotate 240 deg, adjust No.2, rotate 240 deg, adjust No.3.
  6. Four-cylinder: rotate 180 deg, adjust No.3, then No.4, then No.2.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Valve clearance (cold): 0.0057 - 0.0072 in. (0.145 - 0.185 mm)

Source: Kubota service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kubota repair guides →