Kubota D-905 / WG-750 — How to Bleed the Platform Rotator
Maintenance
For the Kubota D-905 / WG-750, from the Kubota service manual.
Browse Kubota generators & specs →
Before you start
- Crushing hazard. Keep hands clear of platform pivot weldment.
Procedure
- Connect clear hose to top bleed valve.
- Open top bleed valve.
- Start engine or turn key to ground control.
- Hold platform rotate switch right 5 seconds, repeat three times.
- Hold left 5 seconds.
- Rotate fully left until air stops.
- Close valve, rotate right to center.
- Repeat for bottom bleed valve.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Kubota service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.