Home›Repair guides›Kubota›Cleaning Air Filter Element

Kubota — Cleaning Air Filter Element

Maintenance · Intake system

From a Kubota service manual — check it applies to your exact model before use.

Browse Kubota generators & specs →

Before you start

  • Never apply oil to the dry element.

Procedure

  1. Use clean dry compressed air on the inside of the element.
  2. Air pressure at the nozzle must not exceed 690 kPa.
  3. Maintain reasonable distance between the nozzle and the filter.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 690 kPa (7 kgf/cm2, 100 psi) max

Source: Kubota service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.