Procedure
- Push down thermostat valve and insert string between valve and valve seat.
- Place thermostat and thermometer in container with water and gradually heat.
- Hold string to suspend thermostat in water.
- When valve opens, it falls from string; read water temperature.
- Continue heating and read temperature when valve completely opened [about 0.236 in. (6 mm)].
- If temperatures are not within standard values, replace thermostat.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Opening temperature: 157.1 - 162.5 °F (69.5 - 72.5 °C)
- Completely open: 185 °F (85 °C)
Source: Kubota service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.