Home›Repair guides›Kubota›Checking and Adjusting Drive Belt Tension

Kubota — Checking and Adjusting Drive Belt Tension

Adjustments · Alternator drive belt

From a Kubota service manual covering: Hurth HBW 100, Hurth HBW 125, Hurth HBW 150, Hurth HBW 250, Hurth HBW 35, Hurth HBW 50, M-25XPB, M-35B, M-40B. Check it applies to your exact model before use.

Browse Kubota generators & specs →

Before you start

  • Never attempt to check or adjust the drive belt's tension while the engine is in operation.

Procedure

  1. Press belt midway between alternator and crankshaft pulleys with 22 lbs (10 kgf).
  2. Belt deflection should be 3/8 - 1/2 in. (10 - 12 mm) deep.
  3. Loosen the alternator adjusting strap bolt and the base mounting bolt.
  4. Inspect belt for damage, wear, cracks and frayed edges; replace if damaged.
  5. Pivot the alternator left or right to loosen or tighten.
  6. Tighten the base mounting bolt and the adjusting strap bolt securely.
  7. Run the engine about 5 minutes, shut down, and recheck belt tension.

Specs & values

  • Belt deflection 3/8 - 1/2 in. (10 - 12 mm)

Source: Kubota service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kubota repair guides →