Before you start
- Keep the injection pump air vent plug closed except when venting air.
Procedure
- Fill the fuel tank with fuel, and open the fuel cock.
- Loosen the air vent plug of the fuel filter a few turns.
- Screw back the plug when bubbles do not come up any more.
- Open the air vent cock on top of the fuel injection pump.
- Retighten the plug when bubbles do not come up any more.