Kohler — Valve Clearance Adjustment
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- Engine must be cold for accurate adjustment.
Procedure
- Ensure engine is cold and at rest.
- Remove valve cover.
- Locate adjustment screw on rocker arm.
- Insert feeler gauge of specified thickness between valve stem and rocker arm.
- Loosen locknut and adjust clearance screw until specified gap is achieved.
- Tighten locknut securely.
- Reinstall valve cover with new gasket.
Tools required
- Feeler gauge
- Socket wrench
Specs & torque values
- Valve clearance specification: 0.15mm (intake/exhaust per manual)
Source: manual:14_690_01_EN.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.