Home›Repair guides›Kohler›TPS Initialization Procedure (Auto-Learn)

Kohler — TPS Initialization Procedure (Auto-Learn)

Testing & diagnosis · Throttle Position Sensor / ECU

From a Kohler service manual covering: LH630, LH685, LH750, LH760. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • If MIL stays on more than 15 seconds, turn off ignition and initiate fault code sequence.

Procedure

  1. Check basic engine, sensors, fuel, fuel pressure, and battery are good.
  2. Remove/disconnect all external loads.
  3. Connect jumper from TPS initialization pin #24 to battery voltage pin.
  4. Start engine and observe MIL blinking 4 times every 2 seconds.
  5. Remove jumper from service connector.
  6. Run engine at full throttle above 3000 RPM to warm up and initiate O2 closed-loop.
  7. When MIL blinks rapidly, move throttle to low idle and adjust to 1500 RPM.
  8. Wait for MIL slow blink then shut off; reconnect loads.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Idle speed 1500 RPM

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.