Kohler TP 4.0 D — Install Pump Case
Installation
For the Kohler TP 4.0 D, from the Kohler service manual.
Browse Kohler generators & specs →
Procedure
- Place a new gasket on back plate.
- Install pump case to back plate and loosely tighten screws, making sure gasket is seated correctly.
- Torque screws to 36.6 N·m (27 ft. lb.).
Tools required
- torque wrench Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Pump case screws: 36.6 N·m (27 ft. lb.)
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.