Home›Repair guides›Kohler›Install Inlet Flange and Check Valve

Kohler TP 4.0 D — Install Inlet Flange and Check Valve

Installation

For the Kohler TP 4.0 D, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Apply Loctite® 587™ Ultra Blue or equivalent to inlet flange screws.
  2. Install inlet flange and check valve to pump case with screws and washers.
  3. Torque screws to 4.1-5.4 N·m (36-48 in. lbs.).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →