Kohler TP 4.0 D — Install Inlet Flange and Check Valve
Installation
For the Kohler TP 4.0 D, from the Kohler service manual.
Browse Kohler generators & specs →
Procedure
- Apply Loctite® 587™ Ultra Blue or equivalent to inlet flange screws.
- Install inlet flange and check valve to pump case with screws and washers.
- Torque screws to 4.1-5.4 N·m (36-48 in. lbs.).
Tools required
- torque wrench Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Inlet flange screws: 4.1-5.4 N·m (36-48 FridayParts $51.99 in. lbs.)
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.