Procedure

  1. Install rotating seal onto shaft and press against back plate.
  2. Turn impeller on by hand clockwise until tight.
  3. Hit 1 blade clockwise to tighten impeller until resistance is observed.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.