Home›Repair guides›Kohler›Install Back Plate

Kohler TP 4.0 D — Install Back Plate

Installation

For the Kohler TP 4.0 D, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Apply Loctite® 587™ Ultra Blue or equivalent to screws.
  2. Replace back plate and hold in position.
  3. Secure with screws and washers.
  4. Torque back plate screws to 17.6-20.3 N·m (13-15 ft. lbs.).

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Back plate screws: 17.6-20.3 N·m (13-15 ft. lbs.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →