Home›Repair guides›Kohler›Air Cleaner Service

Kohler TP 4.0 D — Air Cleaner Service

Maintenance

For the Kohler TP 4.0 D, from the Kohler owner's manual.

Browse Kohler generators & specs →

Before you start

  • Paper element (M) cannot be blown out with compressed air.

Procedure

  1. Loosen air cleaner cover nut (K) and remove air cleaner cover (O).
  2. Precleaner: remove precleaner (N) from paper element (M).
  3. Replace or wash precleaner (N) in warm water with detergent; rinse and air dry.
  4. Saturate precleaner (N) with new engine oil; squeeze out excess oil.
  5. Reinstall precleaner (N) over paper element (M).
  6. Paper element: clean area, remove wing nut (L) and paper element (M) with precleaner (N).
  7. Separate precleaner (N) from paper element (M); replace paper element (M).
  8. Check condition of rubber seal (X) and replace if necessary.
  9. Install new paper element (M) on base; install precleaner (N); secure with wing nut (L).
  10. Reinstall air cleaner cover (O) and secure with cover nut (K).

Source: Kohler owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →