Home›Repair guides›Kohler›Engine Storage (2 months or more)

Kohler TH16 / TH18 — Engine Storage (2 months or more)

Maintenance

For the Kohler TH16 / TH18, from the Kohler service manual.

Browse Kohler generators & specs →

Before you start

  • Do not connect spark plug leads when cranking during storage.

Procedure

  1. Clean exterior surfaces of engine.
  2. Change oil and oil filter while engine is still warm from operation.
  3. Empty fuel system or treat gasoline with stabilizer; run engine 2-3 minutes.
  4. Remove spark plugs and add one tablespoon of engine oil into each spark plug hole; install plugs and ground leads.
  5. Crank engine two or three revolutions.
  6. Store engine in a clean, dry place.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.