Testing & diagnosis

From a Kohler service manual covering: WA 2.0, WA 3.0, WB 2.0, WB 3.0. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. Before running, check oil and slowly pull engine over with retractable starter to ensure nothing is binding.
  2. Fill with prime water and start engine.
  3. After warm up run engine at full throttle and check vacuum with a vacuum tester for leaks.
  4. A vacuum of 20 to 25 lbs. at sea level should be read within 5 seconds.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Vacuum 20 to 25 lbs. at sea level within 5 seconds

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.