Kohler — Testing Pump
Testing & diagnosis
From a Kohler service manual covering: WA 2.0, WA 3.0, WB 2.0, WB 3.0. Check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- Before running, check oil and slowly pull engine over with retractable starter to ensure nothing is binding.
- Fill with prime water and start engine.
- After warm up run engine at full throttle and check vacuum with a vacuum tester for leaks.
- A vacuum of 20 to 25 lbs. at sea level should be read within 5 seconds.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Vacuum 20 to 25 lbs. at sea level within 5 seconds
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.