Home›Repair guides›Kohler›Test for Spark

Kohler — Test for Spark

Testing & diagnosis · Electrical system

From a Kohler service manual covering: EZT715, EZT715-EZT750, EZT725, EZT740, EZT750. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Do not crank engine or perform tests with 1 spark plug lead disconnected and not grounded.

Procedure

  1. With engine stopped, disconnect 1 spark plug lead.
  2. Connect spark plug lead to post terminal of spark tester and attach tester clip to a good engine ground.
  3. Crank engine over, establishing a minimum of 550-600 RPM, and observe tester for spark.
  4. Repeat spark test on opposite cylinder if cylinders are being tested individually.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Cranking speed minimum 550-600 RPM

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.