Kohler — Static Ignition Timing
Adjustments · ignition system
From a Kohler service manual covering: K141, K161, K181, K241, K301, K321, K341, K91. Check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- Remove spark plug lead to prevent unintentional starting.
Procedure
- Remove breaker point cover.
- Remove spark plug lead to prevent unintentional starting.
- Rotate engine slowly clockwise by hand.
- Breaker points should just begin to open when S or SP mark appears in timing sight hole.
- Continue rotating until breaker points are fully opened.
- Measure breaker point gap with feeler gauge; gap should be .020 in.
- Loosen gap adjustment screw and adjust gap if needed.
- Tighten gap adjustment screw and replace cover.
Tools required
- feeler gauge Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Breaker point gap .020 in.
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.