Home›Repair guides›Kohler›Speed Sensor Test

Kohler — Speed Sensor Test

Testing & diagnosis

From a Kohler service manual — check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. With Generator Master Switch in OFF/RESET position, connect a DC voltmeter between positive (+) lead (wire 24) at speed sensor and ground (wire 2). Voltmeter should read approximately 12 Volts DC.
  2. With generator set running, connect DC voltmeter negative probe to “0” terminal (wire 16 - white) on speed sensor. Place voltmeter positive probe on positive (+) terminal (wire 24 - red). Voltmeter sh
  3. If speed sensor is emitting a signal, check continuity of speed sensor leads (wires 2, 16 and 24). If not emitting a signal, test speed sensor through following procedure:
  4. Connect speed sensor, voltmeter and DC voltage source as shown in Figure 3-14.
  5. Touch sensing surface with a flat piece of iron or steel - at least 1/4 cubic inch (4.1 cm).
  6. Voltmeter test reading should equal source voltage.
  7. Remove iron or steel from sensing surface and observe NO test voltmeter reading.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Speed sensor air gap 0.020 in. (0.508 mm)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.