Home›Repair guides›Kohler›Solenoid Tests

Kohler — Solenoid Tests

Testing & diagnosis · Starter solenoid

From a Kohler service manual covering: ECV850, ECV860, ECV870, ECV880. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Do not leave 12V test leads connected longer than necessary.

Procedure

  1. Disconnect all leads from solenoid and separate from starter.
  2. Pull-in actuation: connect 12V to S terminal and lower post; solenoid should click.
  3. Pull-in continuity: ohmmeter across large posts; should indicate continuity.
  4. Hold-in function: connect 12V to S terminal and body; push plunger in; coil should hold.
  5. Hold-in continuity: ohmmeter across large posts; should indicate continuity.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →