Kohler — Solenoid Pull-in Coil Test
Testing & diagnosis · Starter Solenoid
From a Kohler service manual covering: CV682, CV732, CV742, CV752. Check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- DO NOT leave 12 volt test leads connected to solenoid longer than necessary. Internal damage to solenoid may occur.
Procedure
- Use a 12 volt power supply and 2 test leads.
- Connect 1 lead to flat spade S/start terminal on solenoid; momentarily connect other lead to lower large post terminal.
- Solenoid should energize (audible click) and plunger retract; repeat test several times.
- Use an ohmmeter set to audible or Rx2K scale, connect leads to 2 large post terminals and check for continuity.
- Replace solenoid if it fails to activate or no continuity is indicated.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.