Home›Repair guides›Kohler›Solenoid Pull-in Coil Test

Kohler — Solenoid Pull-in Coil Test

Testing & diagnosis · Starter Solenoid

From a Kohler service manual covering: CV682, CV732, CV742, CV752. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • DO NOT leave 12 volt test leads connected to solenoid longer than necessary. Internal damage to solenoid may occur.

Procedure

  1. Use a 12 volt power supply and 2 test leads.
  2. Connect 1 lead to flat spade S/start terminal on solenoid; momentarily connect other lead to lower large post terminal.
  3. Solenoid should energize (audible click) and plunger retract; repeat test several times.
  4. Use an ohmmeter set to audible or Rx2K scale, connect leads to 2 large post terminals and check for continuity.
  5. Replace solenoid if it fails to activate or no continuity is indicated.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.