Procedure

  1. Press Set from the main menu and enter the setup password.
  2. Step to the Set Exerciser menu.
  3. Select the exerciser event number.
  4. Set Enable/Disable.
  5. Set Loaded or Unloaded.
  6. Set the interval and repeat rate.
  7. Set the duration, start date, and start time.
  8. Press Save to save the settings.

Specs & values

  • Up to 21 different exercise events can be scheduled.
  • Maximum run time 24 hours.