Home›Repair guides›Kohler›Separately Excite — Brushless Models (RZ)

Kohler — Separately Excite — Brushless Models (RZ)

Testing & diagnosis · Generator exciter field

From a Kohler service manual covering: 10RMOY, 15RMOY, 15RMY, 15ROY, 17.5ROY, 22.5ROZ, 22.5RZ, 24ROZ, 32.5ROZ, 32.5RZ, 47.5ROZ. Check it applies to your exact model before use.

Applies to: Kohler 15RMY, Kohler 15ROY, Kohler 17.5ROY, Kohler 22.5ROZ, Kohler 22.5RZ, Kohler 24ROZ, Kohler 32.5ROZ, Kohler 32.5RZ, Kohler 47.5ROZ

Procedure

  1. Disconnect and insulate V7, V8, V9, VO and V4 from terminal strip; disconnect and insulate L1, L2 and L3.
  2. Disconnect exciter leads F1 and F2 at quick disconnect.
  3. Place voltmeter across F3 and F4; connect ammeter in series with F3.
  4. Start unit and read battery voltage; ammeter should read 4/10 of 1 amp.
  5. If voltage is not present, problem is in controller; if current is high or low, problem is in the exciter field.
  6. Check L1, L2, L3, V7, V8, V9, VO and V4 with a voltmeter for output (25-35 volts).
  7. If there is output, check the Automatic Voltage Regulation (AVR) circuit.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Full service-parts list: Kohler 15RMY →, Kohler 15ROY →, Kohler 17.5ROY →, Kohler 22.5ROZ →, Kohler 22.5RZ →, Kohler 24ROZ →, Kohler 32.5ROZ →, Kohler 32.5RZ →, Kohler 47.5ROZ →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →