Before you start

  • Hazardous voltage. Moving rotor. Can cause severe injury or death.
  • Open main circuit breaker on all power sources before servicing equipment.

Procedure

  1. Disconnect all leads from voltage regulator.
  2. Connect DC ammeter, 10-amp fuse, and 12-volt battery to brush leads.
  3. Note and record the ammeter reading.
  4. Divide battery voltage by rotor resistance for approximate reading.
  5. Start engine and check ammeter reading; unstable reading indicates fault.
  6. Check for AC output across stator leads.
  7. If rotor and stator test good, voltage regulator is defective.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Rotor resistance 4.7 ohms example
  • Rotor current 2.6 A example

Full service-parts list: Kohler 4CFKM →, Kohler 4CKM →, Kohler 5CKM →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.