Home›Repair guides›Kohler›SCR Module Test

Kohler — SCR Module Test

Testing & diagnosis

From a Kohler service manual covering: 10/15RMOY, 15/17.5ROY, 15RMY, 22.5-47.5ROZ, 22.5/32.5RZ. Check it applies to your exact model before use.

Applies to: Kohler 15RMY

Before you start

  • The SCR module may be damaged if this step is performed incorrectly. Be sure to connect the NEGATIVE (-) lead of the battery to the POSITIVE (+) pin on the SCR module.

Procedure

  1. Check SCR Module with ohmmeter on RX1 Scale.
  2. Connect ohmmeter from (+) to (-): high resistance in one direction and low resistance in the other.
  3. Connect ohmmeter from AC1 to (+): high resistance in both directions. Repeat for AC2.
  4. Connect ohmmeter from AC1 to (-): high in one direction and low in the other. Repeat for AC2.
  5. G1 to (+) should see low resistance in one direction and higher in the other. Repeat for G2.
  6. Connect negative (-) lead from DC source to positive (+) pin on SCR module.
  7. Connect positive (+) lead from DC source, with lamp in series, to AC1 pin on SCR module. Lamp should not glow.
  8. Momentarily connect jumper, with resistor in series, from positive of DC source to G1 pin. Lamp should glow and continue to glow after removing jumper.
  9. Repeat steps 8 and 9 with AC2 and G2. If any check indicates a faulty SCR module - replace.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler 15RMY →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.