Home›Repair guides›Kohler›Replace Pulse Fuel Pump

Kohler — Replace Pulse Fuel Pump

Repair & overhaul · Fuel System

From a Kohler service manual covering: KT715, KT725, KT730, KT735, KT740, KT745. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Make sure orientation of new pump is consistent with removed pump. Internal damage may occur if installed incorrectly.

Procedure

  1. Disconnect fuel lines from inlet, outlet, and pulse fittings on fuel pump.
  2. Remove screws and take off pump.
  3. Connect pulse line to new fuel pump and make sure opposite end is properly connected into valve cover.
  4. Attach new fuel pump using screws. Torque screws to 2.8 N·m (25 in. lb.).
  5. Reconnect fuel lines to inlet and outlet fittings and secure with clamps.

Specs & values

  • 2.8 N·m (25 in. lb.) fuel pump screw torque

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →