Before you start

  • Impeller is heavy.

Procedure

  1. Using a rubber mallet, tap 1 blade counterclockwise to loosen impeller.
  2. Turn impeller counterclockwise by hand until free from crankshaft.
  3. Inspect impeller for cracks and bent blades.
  4. Count and remove shim(s) on crankshaft; replace same number when reassembling.
  5. Pry stuck shims from impeller with a screwdriver; inspect, replace if bent or distorted.
  6. Turn impeller over and remove rotating seal with a small screwdriver, prying upward.
  7. Colored marks on rotating seal will face inward (towards inlet nozzle side of pump).

Tools required