Home›Repair guides›Kohler›Remove and Install Ignition Module (air gap setting)

Kohler — Remove and Install Ignition Module (air gap setting)

Repair & overhaul · ignition system

From a Kohler service manual covering: M10, M12, M14, M16. Check it applies to your exact model before use.

Applies to: Kohler M12, Kohler M16

Procedure

  1. Install module, plain washers, and hex cap sems screws; move module away from flywheel and tighten slightly.
  2. Insert .018 in flat feeler gauge between magnet and module.
  3. Loosen screws so magnet pulls module down; tighten screws to 32 in. lb.
  4. Remove feeler gauge; final air gap should be .012/.016 in.
  5. Rotate flywheel to confirm magnet does not strike module.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Ignition module mounting screw torque 32 in. lb
  • Air gap .012/.016 in

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →