Procedure

  1. Remove generator enclosure access cover.
  2. Disconnect wiring from regulator board and terminal strip; on Basic and Meter Box models also the controller board.
  3. Remove capscrews and lift regulator/terminal strip tray away from generator enclosure.
  4. On NFPA models, feed engine sensor wiring back through opening in generator adaptor.

Tools required

  • Pin extractor (Kohler Part No. 241918) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler 15RMY →, Kohler 15ROY →, Kohler 17.5ROY →, Kohler 22.5ROZ →, Kohler 22.5RZ →, Kohler 24ROZ →, Kohler 32.5ROZ →, Kohler 32.5RZ →, Kohler 47.5ROZ →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.