Kohler — Procedure to Transfer Files
Operation · Controller USB port
From a Kohler service manual — check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- Do not disconnect the device from the USB port during file transfer.
Procedure
- Insert the USB mass storage device into the USB port on the controller's main logic board.
- Press the Download button to load files to the controller, or Upload to load files to the memory device.
- Use the down button to scroll through the list of available files.
- Press the Sel button to select the file and start transferring the file.
- Wait for the completion message before removing the USB device.
Tools required
- USB mass storage device (USB 2.0, Mass Storage Device Class) Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- MPAC1500v###.bin controller application program approx. 950 KB
- MPAC1500_#######.cfg configuration approx. 3 KB
- presentyymmdd.his event history
- alarm_settings.alm common alarms approx. 1 KB
- MPAC1500_cal.cal calibration approx. 1 KB