Procedure
- Disconnect plug from lock-off. Remove nut and lock-off. Remove lock-off valve body and plunger. Discard all parts.
- Install plunger, then lock-off valve body. Torque body to 20 N·m (177 in. lb.).
- Install lock-off assembly and nut. Torque nut to 6.5 N·m (57 in. lb.).
- Reconnect plug to lock-off.
Specs & values
- body 20 N·m (177 in. lb.)
- nut 6.5 N·m (57 in. lb.)
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.