Home›Repair guides›Kohler›Lock-Off Assembly

Kohler PCH680 / PCH740 — Lock-Off Assembly

Repair & overhaul · Fuel Lock-Off

For the Kohler PCH680 / PCH740, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Disconnect plug from lock-off. Remove nut and lock-off. Remove lock-off valve body and plunger. Discard all parts.
  2. Install plunger, then lock-off valve body. Torque body to 20 N·m (177 in. lb.).
  3. Install lock-off assembly and nut. Torque nut to 6.5 N·m (57 in. lb.).
  4. Reconnect plug to lock-off.

Specs & values

  • body 20 N·m (177 in. lb.)
  • nut 6.5 N·m (57 in. lb.)

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.