Kohler PCH680 / PCH740 — Change Oil and Filter
Maintenance · Lubrication System
For the Kohler PCH680 / PCH740, from the Kohler service manual.
Browse Kohler generators & specs →
Procedure
- Clean area around oil fill cap/dipstick and drain plug.
- Remove drain plug and oil fill cap/dipstick. Allow oil to drain completely.
- Remove oil filter. Wipe mounting surface. Reinstall drain plug; torque to 13.6 N·m (10 ft. lb.).
- Prefill new filter with oil; allow 2 minutes.
- Apply thin film of clean oil to rubber gasket.
- Install new filter per instructions.
- Fill crankcase with new oil. Level at top of indicator.
- Start engine; check for leaks. Stop engine; correct leaks. Recheck oil level.
Specs & values
- Oil drain plug 13.6 N·m (10 ft. lb.)
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.