Kohler — Oil Sentry Testing
Testing & diagnosis · Oil Sentry switch
From a Kohler service manual covering: CH18, CH20, CH22, CH23, CH25, CH620, CH630, CH640, CH670, CH680, CH730, CH740…. Check it applies to your exact model before use.
Applies to: Kohler CH18, Kohler CH740
Procedure
- Connect continuity tester across blade terminal and metal case of switch. With 0 psi applied, tester should indicate continuity (switch closed).
- Gradually increase pressure; through range of 3-5 psi tester should change to no continuity (switch open). Switch should remain open as pressure increased to 90 psi maximum.
- Gradually decrease pressure through 3-5 psi; tester should change to continuity (switch closed) down to 0 psi.
- Replace switch if it does not operate as specified.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- 3-5 psi
- 90 psi maximum
Full service-parts list: Kohler CH740 →
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.