Kohler — Oil Sentry Switch Installation to Crankcase Boss
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Procedure
- Remove the 1/16" NPTF pipe plug (or old switch and 1/8" x 1/16" NPTF reducer) from crankcase.
- Apply Loctite #592 Teflon sealant (or equivalent) to threads of switch. Install reducer to switch and tighten securely.
- Apply Loctite #592 Teflon sealant (or equivalent) to threads of reducer. Install reducer/switch assembly into crankcase. Tighten the reducer securely into the crankcase.
Specs & torque values
- Loctite #592 Teflon sealant
- 1/16" NPTF pipe plug
- 1/8" x 1/16" NPTF reducer
Source: manual:tp_2289_a.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.