Home›Repair guides›Kohler›Multi-Tap Voltage Configuration Change

Kohler — Multi-Tap Voltage Configuration Change

Adjustments · Voltage transformers

From a Kohler service manual — check it applies to your exact model before use.

Browse Kohler generators & specs →

Before you start

  • Verify that the transfer switch voltage matches the system voltage.

Procedure

  1. Before connecting power, change the voltage taps of the potential transformers (PTs) to match the system voltage.
  2. After taps are set, connect the contactor harness to the controller (through the control circuit isolation switch, if equipped).
  3. When power is connected to the ATS controller, change the system voltage setting on the controller.
  4. Order a new nameplate from the Aftermarket Parts department, providing ATS model and serial numbers and the new voltage setting.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.