Before you start
- Electrostatic discharge (ESD) damages electronic circuit boards. Wear an approved grounding wrist strap.
Procedure
- If the display shows Module Status Change, press the button labelled Reset.
- If the display shows Check Module Setup to Clear Fault, press Main to return to the main screen.
- Press Set to enter setup mode and enter the setup password.
- Press the down arrow to step to the Set Inputs/Outputs screen.
- Navigate to the Set Auxiliary I/O screen.
- Press the right arrow to see the status of module 1; step to modules showing Status: Lost.
- Press the right arrow to move to the Uninstall Module screen; verify the screen says Uninstall Module Yes.
- Press Save to uninstall the module.
- Repeat the uninstall procedure for additional modules, if necessary.