Home›Repair guides›Kohler›Module Uninstall Procedure

Kohler MPAC 1200 / MPAC 1500 — Module Uninstall Procedure

Repair & overhaul · Accessory module

For the Kohler MPAC 1200 / MPAC 1500, from the Kohler service manual.

Browse Kohler generators & specs →

Before you start

  • Electrostatic discharge (ESD) damages electronic circuit boards. Wear an approved grounding wrist strap.

Procedure

  1. If the display shows Module Status Change, press the button labelled Reset.
  2. If the display shows Check Module Setup to Clear Fault, press Main to return to the main screen.
  3. Press Set to enter setup mode and enter the setup password.
  4. Press the down arrow to step to the Set Inputs/Outputs screen.
  5. Navigate to the Set Auxiliary I/O screen.
  6. Press the right arrow to see the status of module 1; step to modules showing Status: Lost.
  7. Press the right arrow to move to the Uninstall Module screen; verify the screen says Uninstall Module Yes.
  8. Press Save to uninstall the module.
  9. Repeat the uninstall procedure for additional modules, if necessary.

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →