Before you start

  • Read all Safety Precautions before disassembling the generator set.

Procedure

  1. Remove controller cover screws and lift away cover.
  2. Remove capscrews and tilt back enclosure access cover/controller.
  3. Disconnect all wiring between controller and generator enclosure.
  4. Disconnect canvas support strap in generator enclosure.
  5. Lift controller/access cover away from generator enclosure.

Full service-parts list: Kohler 15RMY →, Kohler 15ROY →, Kohler 17.5ROY →, Kohler 22.5ROZ →, Kohler 22.5RZ →, Kohler 24ROZ →, Kohler 32.5ROZ →, Kohler 32.5RZ →, Kohler 47.5ROZ →