Procedure
- Press RESET MENU, then digit keys 1, 3 to obtain the Remote Control submenu.
- Check options ON-LINE, LOCAL, REMOTE, LAN, and REMLAN and enter the appropriate response.
- For REMOTE, check the Options Locked submenu and note the Clock #; enter the same ID used in the monitor software.
- For LAN, enter the Local Area Network address number between 1 and 128.
- Check/set the BAUD RATE in Index 13 (default 9600; choices 2400, 4800, 9600).
- Press RESET MENU then ENTER to store the setpoints.
Specs & values
- baud rate default 9600; choices 2400, 4800, 9600
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.