Kohler M340 — Keypad And Status Panel
Testing & diagnosis · Status panel / logic board
For the Kohler M340, from the Kohler service manual.
Browse Kohler generators & specs →
Procedure
- Test the keypad by pressing a key and checking the response. If the response is ever incorrect, the keypad is defective; replace the logic board assembly.
- Press the LAMP TEST key on the keypad.
- If some LEDs are on but at least one is not, the status panel is defective; replace the logic board assembly.
- If some LCD character blocks appear black but at least one does not, replace the logic board assembly.
- If no LEDs are on and character blocks are black, verify power and check the P2 and P4 ribbon cable connections.
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.