Kohler — LOW COMPRESSION
A Kohler service procedure — check it applies to your exact model before use.
Browse Kohler generators & specs →
Before you start
- Early KT17 models have the breather
Procedure
- Air cleaner base must be flat on gasket of air intake elbow. Replace base if bent or cracked.
- Gasket surfaces of element must be flat against base and cover to seal effectively.
- Cover seal must be in place to reduce noise and vibration of cover. Excess vibration can cause stud hole in cover to enlarge, permitting dirt to enter carburetor.
- Wing nut must be finger tightened 1/2 to 1 full turn after nut contacts cover—do not over¬ tighten. Refer to the instructions for the specific type of air cleaner being serviced. Tear Drop (Figure 3-1) Disassembly
- Remove the wing nut, cover, air cleaner cover seal, and element.
- Remove the breather hose and air intake tube from air cleaner base.
- Remove the screws securing base to intake elbow. Lift base from intake elbow. Assembly
- Install air cleaner base and new base gasket on elbow and secure with four 10-32 x 9/16” hex washer head screws. Secure base to manifold with hex nut on manifold stud.
- Pull end of breather tube through 9/16” hole in base making sure lips on end of tube seal securely around hole in base. NOTE: Early KT17 models have the breather
Source: manual:16304_text.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.