Home›Repair guides›Kohler›Long-Term Storage Preparation

Kohler — Long-Term Storage Preparation

Maintenance · Engine

From a Kohler operator's manual covering: KG6208, KG6208TAHD, KG6208TASD. Check it applies to your exact model before use.

Browse Kohler generators & specs →

Procedure

  1. Change the engine oil and filter.
  2. Remove the drive belt.
  3. Disconnect spark plug wires and remove spark plugs.
  4. Squirt approximately 30 ml (1 ounce) of fresh engine oil into each cylinder.
  5. Manually rotate the crankshaft 10-15 times.
  6. Install spark plugs and reconnect spark plug wires.
  7. Cover exposed metal parts with protectant.
  8. Coat electrical connectors with protectant.

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.