Procedure

  1. Perform all short-term storage tasks
  2. Change the engine oil and filter, then remove the drive belt
  3. Disconnect spark plug wires and remove the spark plugs
  4. Squirt about 30 ml (1 oz.) of fresh oil into each cylinder
  5. Manually rotate the crankshaft 10-15 times to distribute the oil
  6. Reinstall the spark plugs and reconnect the wires
  7. Coat exposed metal parts and electrical connectors with protectant

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.