Procedure
- Perform all short-term storage tasks
- Change the engine oil and filter, then remove the drive belt
- Disconnect spark plug wires and remove the spark plugs
- Squirt about 30 ml (1 oz.) of fresh oil into each cylinder
- Manually rotate the crankshaft 10-15 times to distribute the oil
- Reinstall the spark plugs and reconnect the wires
- Coat exposed metal parts and electrical connectors with protectant
Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.