Home›Repair guides›Kohler›Valve Adjustment (Valve-Tappet Clearance)

Kohler L600 / L654 — Valve Adjustment (Valve-Tappet Clearance)

Adjustments · Valve mechanism

For the Kohler L600 / L654, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Remove spark plugs then turn engine over until #1 piston is at Top Dead Center on compression stroke (both valves closed).
  2. Insert feeler gauge between tappet and end of exhaust valve; adjust tappet setscrew for very slight drag on the gauge.
  3. Repeat procedure on intake valve on #1 cylinder.
  4. Turn engine over until next piston is at TDC compression and repeat in turn on each cylinder until all valves are adjusted.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Intake clearance .008 in cold
  • Exhaust clearance .011 in cold

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.