Kohler L600 / L654 — Magneto Breaker Point Service and Gap Setting
Maintenance · Magneto breaker points
For the Kohler L600 / L654, from the Kohler service manual.
Applies to: Kohler L600 engine
Procedure
- After each 500 hours remove magneto end cap and check breaker points.
- If dirty, clean with lacquer thinner and a coarse lint free cloth.
- Dress slight pitting with a tungsten file or fine stone; replace points if badly worn or pitted.
- Turn engine until points are wide open at highest point on cam; maximum opening should be .015 inch.
- Loosen clamp screws, insert blade in adjusting slot and shift plate until .015 inch maximum clearance is measured, then retighten clamps.
- Lubricate cam wick with Rycon grease each time breaker points are serviced.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Breaker point gap .015 inch
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.