Kohler L600 / L654 — Magneto Breaker Point Gap Adjustment

Adjustments

For the Kohler L600 / L654, from the Kohler service manual.

Browse Kohler generators & specs →

Procedure

  1. Turn engine over until points are wide open (at highest point on cam).
  2. Loosen clamp screws slightly so contact plate can be moved.
  3. Insert blade in adjusting slot then shift plate until .019 in maximum clearance is measured between contacts.
  4. Retighten clamps after adjustment.
  5. Lubricate cam wick with Rycon grease each time breaker points are serviced.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • .019 in maximum clearance

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.