Kohler L600 / L654 — Magneto Breaker Point Gap Adjustment
Adjustments
For the Kohler L600 / L654, from the Kohler service manual.
Browse Kohler generators & specs →
Procedure
- Turn engine over until points are wide open (at highest point on cam).
- Loosen clamp screws slightly so contact plate can be moved.
- Insert blade in adjusting slot then shift plate until .019 in maximum clearance is measured between contacts.
- Retighten clamps after adjustment.
- Lubricate cam wick with Rycon grease each time breaker points are serviced.
Tools required
- blade/feeler gauge Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- .019 in maximum clearance
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.